Air Projet Plus 2018 Pic Solution Medical Device Device for aerosol therapy. | Silent and fast, therefore ideal for children | The design has been specifically studied to make therapeutic treatment simpler and more practical thanks to the rotation system of the device and the connecting tube which allow the therapy to be carried out comfortably following the movements of the child. bambino.| Accessori Included: AirSoft 2 in 1 mask, nosepiece, mouthpiece, connection tube. | Equipped with aerosol bag. | Indications for use: For aerosol therapy treatment | Medical device according to Directive 93/42 EEC | Amended by Directive 2007/47/EC | Implemented by Legislative Decree no. 37 of 25-01-2010 | Class IIa | Compliance with EN 60601-1-2 | EN 60601-1 | CLEANING AND MAINTENANCE Before cleaning and maintaining the tank, turn off the appliance (if on) by pressing the power switch button (M) and remove the plug of the removable mains connection cable (L) from the power socket and disconnect the removable cable connector from the appliance. | Warning! Never immerse or wet the appliance in water or other liquids. | To clean the medicine tank from any residue, use only a soft, clean cloth slightly moistened with warm water. una Thorough cleaning of all surfaces of the drug tank (I), especially in the areas where they intersect. Cleaning operations must be carried out at the end of each therapeutic session. Do not use cleaning substances that could damage the device. Cleaning and maintenance of the accessori Separate all the accessori (mask, mouthpiece, fork, and tube) used and rinse them under running water. | WARNING! Do not boil the mask. Disinfect the parts that come into contact with the patient with cold denatured alcohol. It is recommended to clean and check the integrity of the accessori before and after each use and replace them if damaged. | Thoroughly dry all components and the appliance before putting it away. | Store the appliance in a cool, dry place away from light and heat sources. | Never use benzene, thinners or other flammable chemicals for cleaning. For una greater hygienic safety, never use the same ones accessori for more than one patient, but purchase a dedicated kit for each user. | Disposal In accordance with current legislation | Warnings for use Before use, carefully read and understand the information contained in this manual and keep it for further reference. | Device intended for aerosol therapy. Always follow the doctor's instructions on the type of medication to use, the dosage, frequency and duration of inhalations. Any use other than that for which the device is intended is to be considered improper and therefore dangerous; Pikdare cannot essere considered responsible for damages caused by improper, incorrect and/or unreasonable use or if the appliance is used in electrical systems that do not comply with current safety standards. After removing the appliance from the packaging, make sure that it is intact, without visible damage that could essere caused by transport. If in doubt, do not use the appliance and contact the Technical Assistance Centre. PiC.| Keep out of reach of children gli elementi packaging (bags, box, etc.) as they are potential sources of danger.| Before connecting the appliance, make sure that the data on the rating plate corresponds to those of your electrical distribution network. The data on the rating plate is located on the bottom of the appliance.| If the appliance plug and the mains socket are incompatible, use adapters certified in accordance with the regulations in force in individual countries.| To prevent overheating and damage to the appliance, it is necessary to turn it off for 30 minutes after every 15 minutes of operation.| Warning! Inadequate cooling of the appliance before using it again could result in excessive overheating and consequent intervention of the thermal protection devices.| Do not use the appliance in the presence of nitrous oxide, oxygen or a flammable anesthetic mixture with air.| Turn off the appliance and unplug it from the mains after each use and before adding other medication.| Keep the appliance and the power cord away from hot surfaces.| Do not use the appliance while fa the bath or shower or in a humid environment, or near bathtubs, sinks, washbasins, and so on. | Never touch the appliance with wet or damp hands. | Never drop or immerse the appliance in water or other liquids. If this happens, turn off the main switch, unplug the appliance, never use it, and contact technically qualified personnel. | Do not use the appliance if you are drowsy or sleepy. | Do not use the appliance in humid environments. dove Sprays have just been used: ventilate the room before proceeding with the therapy. Do not block or obstruct the air vents of the device. Do not insert any objects into the cooling vents. Do not pull the power cord or the device itself to unplug it from the socket. If children or persons with reduced physical or cognitive abilities use the device, adequate supervision is necessary. The device contains small parts that can become detached. essere accidentally ingested. Children should essere supervised to ensure that they do not play with the appliance. Do not use fittings or accessori not foreseen by the manufacturer. | Make sure that the appliance is placed during use (and stored) on flat and stable surfaces to prevent any overturning. | The support surface, during use, must essere free from objects that may obstruct the correct airflow.| Never leave the plug inserted into the power socket when the appliance is not in use or when it is unattended.| Before carrying out any cleaning or maintenance operation, disconnect the appliance from the power supply by unplugging it from the power socket.| If you decide not to use this appliance any longer, after unplugging it from the power socket, we recommend rendering it inoperative by cutting the power cable. We also recommend rendering harmless any parts of the appliance that could constitute a danger, especially for children.| For the disposal of accessori subject to wear, refer to current legislation. Do not dispose of the appliance as normal urban waste, carry out separate collection as electrical/electronic equipment (WEEE) as required by current laws and EC directives. This appliance must no longer essere used if, after having undergone una If it has fallen, appears damaged or deteriorated in any part. If in doubt, contact the Technical Assistance Centre. Pic .• In the event of a fault and/or malfunction of the appliance, turn it off by unplugging it from the power socket and contact the Assistance Centre exclusively. PiC. Do not attempt to open or tamper with the device. | Medical electrical equipment requires special precautions regarding electromagnetic compatibility: install and put this device into service according to the electromagnetic compatibility information in the user manual. | Caution: Portable and mobile RF communications equipment can affect medical electrical equipment. | Caution: Do not use the device adjacent to or stacked with other equipment. | Preparing and using the device Remove the device and its accessori from the packaging or aerosol bag;| WARNING! Carefully check the surface of the medicine container and all components before each use. If there is any visible damage or breakage, do not use the device and contact the Technical Assistance Center. PiC;| Lift the lid of the medicine tank;| Introduce the medicine into the appropriate tank, following the doses recommended by the doctor or pharmacist;| The contents of the tank must never exceed the reference mark on the tank itself.| The maximum capacity of the medicine tank is 8 ml; any solution of a larger volume must essere divided into multiple inhalations;| The minimum capacity of the drug tank is 3 ml; a smaller volume of solution must essere diluted with 7% saline solution, unless otherwise specified on the drug's instruction sheet; Close the tank lid, checking that it is closed correctly; Choose the most suitable accessory with which you want to carry out the therapy: mask, mouthpiece, nosepiece (applied parts). If in doubt, consult your doctor or pharmacist. Ultrasonic Aerosol Device | FAST AND SILENT: an aerosol therapy device with ultrasound technology, fast and silent with a compact DLS design | COMPLETE AND COMFORTABLE: thanks to the rapid and silent nebulization, it is ideal for contributing to the well-being of the breath | PRACTICAL TO USE: the particular design and ultrasound technology make it immediately pronto Easy to use and clean in just a few steps after therapy | HIGH FREQUENCY TECHNOLOGY: High frequency sound waves propagate in the liquid and break up the solution, transforming it into a fine mist | INCLUDES: AirProjet Plus aerosol, connecting tube, mouthpiece, fork, una Soft “2 in 1” mask, which easily adapts to the face of adults and children and practical bag Silent aerosol for adults and children | Details Rapid and silent nebulization | Offers una quick and silent nebulization: thanks to the internal ultrasonic system, AirProjet Plus takes little time tempo to finalize the aerosol therapy and does not require water, only the drug. | The ultrasound system | Nebulization occurs thanks to high-frequency sound waves that propagate in the water and break up the solution, nebulizing it. | Designed for those who want everything at hand | The accessori make aerosol therapy more comfortable and can essere stored in una A handy bag for carrying it around with ease, protecting it from bumps. | WHAT IS DLS DESIGN? It's the acronym for Design Language Solution, the product development philosophy Pic Born from people's needs and inspired by the forms of nature. Simplicity: the request of Italian families was clear, and we took up the challenge with our usual enthusiasm and passion. The rounded shapes, the dominant white color, and the handles redesigned for essere Comfortable and intuitive, clearly visible displays, smaller buttons for ease of use and speed, slim and reassuring silhouettes: these are just some of the improvements we've made to our products, now it's up to you to experience them firsthand. | It is a CE 0068 Medical Device. Ministerial Authorization dated 10/12/2021 | Read the warnings or instructions for use carefully. | Format: Pack of 1 piece.
Free shipping on all orders from Europe above 99 €
GLOBAL SERVICE
-
Shipping all over the world, TAXES AND CUSTOMS INCLUDED