L'espace SPACER CHAMBER FOR INHALER INHALER | | Indications | Sealing chamber with valve that helps use metered dose inhalers (MDI). It improves the effectiveness of drug delivery to the lungs by reducing side effects. | | Dosage and Directions for Use | 1 - Before use, carefully examine the product to ensure it is assembled correctly and that there are no foreign objects or missing components. Remove any foreign objects before use. | 2 - Before use, read the instructions provided with the MDI. Remove the lid from the MDI; | 3 - Insert the MDI into the bottom; | 4 - Apply the mask to the face and ensure there is una complete adhesion between the mask and face. To prevent crushing of the mask, hold the device in modo Hold both the mask and the chamber with your hand; | 5- Press the MDI and inhale slowly through your mouth. Keep the mask firmly pressed against your face for at least 5 breaths after pressing the inhaler. During inhalation, air enters through the openings at the bottom, facilitating the inhalation of the nebulized solution. The exhaled air exits through the exhalation valve; | 6- Wait 30 seconds before administering another dose of medication (repeat steps 4-5), or as directed by your doctor. Administer only one puff of medication at a time and follow your doctor's dosing instructions. | | Characteristics | The product does not contain latex. | | Cleaning instructions | If the device is always used by the same person persona clean it as indicated. If the device is used by more than one person, it is necessary, after each use, in addition to cleaning, also una sterilization in an autoclave at 121°C for 15 minutes. The device can essere sterilized without compromising its functional characteristics up to 20 times, after which it must be replaced. If deemed appropriate, for una For thorough cleaning, you can boil the device or wash it in the dishwasher. | A - the product should essere clean following the instructions below before first use and then at least una Once a week: remove the bottom and mask; | B - Soak the parts for 15 minutes in warm water with a neutral detergent and disinfectant. Shake gently; | C - Rinse in clean water; | D - Shake to remove excess water as shown. Do not use dry cloths to dry the device parts. Make sure the parts are dry before reassembling them; | E - Replace the bottom and mask when the parts are completely dry and ready for use. Center the alignment arrow on the back component with the alignment notch on the body as shown. | | Warnings | Replace the product if a component is damaged. Some components may be slightly damaged due to their size. essere swallowed by children. Do not leave these components unattended. Adult supervision is always required. Do not disassemble the product beyond the instructions for cleaning. If in doubt about the use of the product, consult your doctor or pharmacist. Clean the product only as directed in these instructions to ensure its effective functioning. | | Storage | When not in use, store the product in a clean container. | Replace the product after 24 months of continuous use. | | Formats | - Yellow background: mask for children 2-6 years; | - Orange background: mask for children 0-2 years; | - Magenta background: mask for adults. | | Code 471352 / 471351 / 471386
Free shipping on all orders from Europe above 99 €
GLOBAL SERVICE
-
Shipping all over the world, TAXES AND CUSTOMS INCLUDED